{"product_id":"uhv-e-beam-heating-station","title":"UHV E-Beam Heating Station for Flag Style Sample Holders – Up to 2000 °C","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUHV E-Beam Heating Station\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a fully assembled electron bombardment heating system designed for high-temperature sample preparation, annealing and surface science applications under \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eultra-high vacuum (UHV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for temperatures from room temperature up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2000 °C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the system accommodates Flag Style Sample Holder Plates and enables high-temperature treatment of samples within a vacuum chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe complete heating station is mounted on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDN40CF (2.75\") flange\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including the heating assembly, internal wiring and electrical feedthroughs. Different receiver orientations and mechanical configurations are available, including fixed-shaft and linear-rotary versions for precise sample positioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eElectron Bombardment Heating\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eElectron bombardment heating uses electrons emitted from a heated filament and accelerated towards the heating assembly to generate high temperatures under vacuum conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system is suitable for thermal annealing, surface preparation, sample cleaning and materials research where temperatures beyond those achievable with conventional resistance heating are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe maximum achievable sample temperature depends on the sample material, dimensions, mounting configuration and thermal conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMechanical Configuration and Manipulation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe heating station is available with a fixed shaft or an integrated linear-rotary vacuum feedthrough, allowing the configuration to be adapted to the chamber geometry and experimental requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLinear-Rotary Feedthrough Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting flange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN40CF (2.75\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear travel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 or 200 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum linear force\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRotation range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±166.75°\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum bakeout temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating pressure range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 10⁻¹¹ to 1000 mbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe linear-rotary configuration combines axial translation and rotation, enabling controlled sample positioning between different locations within a vacuum chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSample Holder Compatibility and Receiver Orientation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe heating station is designed for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSHOM Flag Style Sample Holder Plates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing a removable sample mounting arrangement for transfer, heating and subsequent analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThree receiver orientations are available to accommodate different chamber configurations and sample transfer geometries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOrientation 01 – Flag Perpendicular, Side Insertion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Flag Style Sample Holder is positioned perpendicular to the manipulator axis, with lateral sample insertion and a ±90° receiver orientation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOrientation 02 – Flag Perpendicular, Front Insertion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Flag Style Sample Holder is positioned perpendicular to the manipulator axis, with straight insertion from the front.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOrientation 03 – Flag In-Line with Axis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Flag Style Sample Holder is aligned with the manipulator axis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe appropriate orientation depends on the chamber layout, sample transfer mechanism and available manipulation space.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eElectrical Feedthroughs and Connections\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe complete assembly includes internal wiring and electrical feedthroughs for the electron bombardment heating system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e4-Pin MS12 Type Feedthrough – CF16\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis feedthrough features molybdenum contact pins and a maximum voltage rating of 12 kV. The air-side connector is included; the connecting cable is not included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1-Pin SHV Type Feedthrough – CF16\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe SHV feedthrough has a maximum voltage rating of 5 kV. The air-side connector is included; the connecting cable is not included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll vacuum-exposed components are manufactured from UHV-compatible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eExternal Power Supply Requirements\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOperation of the E-Beam Heating Station requires two external power supplies, which are not included in the scope of delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Voltage Power Supply\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eA CE-marked DC high-voltage power supply with an adjustable output range of 0–1.5 kV and approximately 600 W output power is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supply should provide adjustable current limiting and output current readback with approximately 1 mA resolution.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLow-Voltage Filament Power Supply\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eA conventional CE-marked laboratory DC power supply with an adjustable output range of 0–30 V and approximately 100–200 W output power is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable current limiting and output current readback are required for controlled filament operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe power supplies must be selected and configured according to the electrical requirements of the heating assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTemperature Measurement and Sample Bias\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe standard configuration is supplied \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewithout a thermocouple\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA thermocouple installed in direct electrical contact with the sample plate may be exposed to the applied sample bias voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen high sample bias voltages are applied, the thermocouple connector must be disconnected unless the connected temperature measuring equipment is specifically designed and rated for the corresponding voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eApplications requiring a grounded sample plate, electrical isolation or a specific filament potential should be reviewed individually before selecting the appropriate heating configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eScope of Delivery\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe E-Beam Heating Station is supplied as a fully assembled vacuum-compatible heating system mounted on a DN40CF flange, including the selected mechanical configuration, heating assembly, internal wiring, electrical feedthroughs, air-side connectors and packaging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e External high-voltage power supply, filament power supply, connecting cables, heating controller and thermocouple.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCustom Configurations and Technical Support\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDifferent receiver orientations, manipulator configurations and linear travel lengths are available to accommodate individual chamber geometries and experimental requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor custom UHV applications, special sample mounting arrangements or specific electrical configurations, please contact \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUHV Store of Switzerland\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to discuss your technical requirements.\u003c\/span\u003e\u003c\/p\u003e","brand":"Ferrovac AG","offers":[{"title":"Flag perpendicular side insertion ±90° \/ Fixed Shaft - 171 mm retracted","offer_id":49525555364116,"sku":"HSASOM40(EB)-0171-0001 A","price":15860.0,"currency_code":"CHF","in_stock":true},{"title":"Flag perpendicular side insertion ±90° \/ Linear-Rotary 100 mm travel - 171 mm retracted","offer_id":51939112452372,"sku":"HSASOM40(EBMD)-0100-0171-0001 F","price":16980.0,"currency_code":"CHF","in_stock":true},{"title":"Flag perpendicular side insertion ±90° \/ Linear-Rotary 200 mm travel - 201 mm retracted","offer_id":51939112485140,"sku":"HSASOM40(EBMD)-0200-0201-0001 F","price":16980.0,"currency_code":"CHF","in_stock":true},{"title":"Flag perpendicular front insertion \/ Fixed Shaft - 171 mm retracted","offer_id":49525555396884,"sku":"HSASOM40(EB)-0171-0002 F","price":15860.0,"currency_code":"CHF","in_stock":true},{"title":"Flag perpendicular front insertion \/ Linear-Rotary 100 mm travel - 171 mm retracted","offer_id":51939112517908,"sku":"HSASOM40(EBMD)-0100-0171-0002 F","price":16980.0,"currency_code":"CHF","in_stock":true},{"title":"Flag perpendicular front insertion \/ Linear-Rotary 200 mm travel - 201 mm retracted","offer_id":51939112550676,"sku":"HSASOM40(EBMD)-0200-0201-0002 F","price":16980.0,"currency_code":"CHF","in_stock":true},{"title":"Flag in-line with axis \/ Fixed Shaft - 171 mm retracted","offer_id":49525555429652,"sku":"HSASOM40(EB)-0171-0003 F","price":15860.0,"currency_code":"CHF","in_stock":true},{"title":"Flag in-line with axis \/ Linear-Rotary 100 mm travel - 171 mm retracted","offer_id":51939112583444,"sku":"HSASOM40(EBMD)-0100-0171-0003 F","price":16980.0,"currency_code":"CHF","in_stock":true},{"title":"Flag in-line with axis \/ Linear-Rotary 200 mm travel - 201 mm retracted","offer_id":51939112616212,"sku":"HSASOM40(EBMD)-0200-0201-0003 F","price":16980.0,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/0360\/9364\/files\/HSASOM40_EBMD.png?v=1770132735","url":"https:\/\/uhvstore.com\/products\/uhv-e-beam-heating-station","provider":"UHV Store of Switzerland - Ultra High Vacuum Technology","version":"1.0","type":"link"}