Ferrovac AG
UHV E-Beam Heating Station for Flag Style Sample Holders – Up to 2000 °C
UHV E-Beam Heating Station for Flag Style Sample Holders – Up to 2000 °C
Couldn't load pickup availability
The UHV E-Beam Heating Station is a fully assembled electron bombardment heating system designed for high-temperature sample preparation, annealing and surface science applications under ultra-high vacuum (UHV) conditions.
Designed for temperatures from room temperature up to 2000 °C, the system accommodates Flag Style Sample Holder Plates and enables high-temperature treatment of samples within a vacuum chamber.
The complete heating station is mounted on a DN40CF (2.75") flange, including the heating assembly, internal wiring and electrical feedthroughs. Different receiver orientations and mechanical configurations are available, including fixed-shaft and linear-rotary versions for precise sample positioning.
Electron Bombardment Heating
Electron bombardment heating uses electrons emitted from a heated filament and accelerated towards the heating assembly to generate high temperatures under vacuum conditions.
The system is suitable for thermal annealing, surface preparation, sample cleaning and materials research where temperatures beyond those achievable with conventional resistance heating are required.
The maximum achievable sample temperature depends on the sample material, dimensions, mounting configuration and thermal conditions.
Mechanical Configuration and Manipulation
The heating station is available with a fixed shaft or an integrated linear-rotary vacuum feedthrough, allowing the configuration to be adapted to the chamber geometry and experimental requirements.
Linear-Rotary Feedthrough Specifications
| Parameter | Specification |
|---|---|
| Mounting flange | DN40CF (2.75") |
| Linear travel | 100 or 200 mm |
| Maximum linear force | 30 N |
| Rotation range | ±166.75° |
| Maximum torque | 0.5 Nm |
| Maximum bakeout temperature | 150 °C |
| Operating pressure range | 1 × 10⁻¹¹ to 1000 mbar |
The linear-rotary configuration combines axial translation and rotation, enabling controlled sample positioning between different locations within a vacuum chamber.
Sample Holder Compatibility and Receiver Orientation
The heating station is designed for compatible SHOM Flag Style Sample Holder Plates, providing a removable sample mounting arrangement for transfer, heating and subsequent analysis.
Three receiver orientations are available to accommodate different chamber configurations and sample transfer geometries.
Orientation 01 – Flag Perpendicular, Side Insertion
The Flag Style Sample Holder is positioned perpendicular to the manipulator axis, with lateral sample insertion and a ±90° receiver orientation.
Orientation 02 – Flag Perpendicular, Front Insertion
The Flag Style Sample Holder is positioned perpendicular to the manipulator axis, with straight insertion from the front.
Orientation 03 – Flag In-Line with Axis
The Flag Style Sample Holder is aligned with the manipulator axis.
The appropriate orientation depends on the chamber layout, sample transfer mechanism and available manipulation space.
Electrical Feedthroughs and Connections
The complete assembly includes internal wiring and electrical feedthroughs for the electron bombardment heating system.
4-Pin MS12 Type Feedthrough – CF16
This feedthrough features molybdenum contact pins and a maximum voltage rating of 12 kV. The air-side connector is included; the connecting cable is not included.
1-Pin SHV Type Feedthrough – CF16
The SHV feedthrough has a maximum voltage rating of 5 kV. The air-side connector is included; the connecting cable is not included.
All vacuum-exposed components are manufactured from UHV-compatible materials.
External Power Supply Requirements
Operation of the E-Beam Heating Station requires two external power supplies, which are not included in the scope of delivery.
High-Voltage Power Supply
A CE-marked DC high-voltage power supply with an adjustable output range of 0–1.5 kV and approximately 600 W output power is recommended.
The supply should provide adjustable current limiting and output current readback with approximately 1 mA resolution.
Low-Voltage Filament Power Supply
A conventional CE-marked laboratory DC power supply with an adjustable output range of 0–30 V and approximately 100–200 W output power is recommended.
Adjustable current limiting and output current readback are required for controlled filament operation.
The power supplies must be selected and configured according to the electrical requirements of the heating assembly.
Temperature Measurement and Sample Bias
The standard configuration is supplied without a thermocouple.
A thermocouple installed in direct electrical contact with the sample plate may be exposed to the applied sample bias voltage.
When high sample bias voltages are applied, the thermocouple connector must be disconnected unless the connected temperature measuring equipment is specifically designed and rated for the corresponding voltage.
Applications requiring a grounded sample plate, electrical isolation or a specific filament potential should be reviewed individually before selecting the appropriate heating configuration.
Scope of Delivery
The E-Beam Heating Station is supplied as a fully assembled vacuum-compatible heating system mounted on a DN40CF flange, including the selected mechanical configuration, heating assembly, internal wiring, electrical feedthroughs, air-side connectors and packaging.
Not included: External high-voltage power supply, filament power supply, connecting cables, heating controller and thermocouple.
Custom Configurations and Technical Support
Different receiver orientations, manipulator configurations and linear travel lengths are available to accommodate individual chamber geometries and experimental requirements.
For custom UHV applications, special sample mounting arrangements or specific electrical configurations, please contact UHV Store of Switzerland to discuss your technical requirements.